
ECHO is a new approach to plant operations for utilities. EnviroSim has many years of project experience providing engineering services. We are combining decades of engineering excellence with the powerful BioTwin simulation platform.
The list below is a snapshot of some of EnviroSim’s past engineering services experience.
Experimental Services
- Nitrification kinetics and wastewater characteristics measurement for Salt Lake City Water Reclamation Facility (Salt Lake City, UT)
- Nitrification kinetics and wastewater characteristics measurement for Susquehanna WWTP (Lancaster, PA)
- Rochester WRP (Rochester, MN) nitrification kinetics using Washout method and inhibition screening using SNR tests
- Brighton WWTP (Brighton, ON) nitrification kinetics inhibition screening using SNR tests
- Ashbridges Bay Treatment Plant (Toronto, ON) wastewater characteristics and nitrification kinetics using lab-scale sequencing batch reactor method
- South River WRC (Atlanta, GA) nitrification kinetics using Washout method and inhibition screening using SNR tests
- Thames Water Beckton STW (London, United Kingdom) screening of plant recycles for nitrification inhibition using SNR tests
- Brantford WWTP (Brantford, ON) nitrification kinetics inhibition screening using SNR tests
- Southwest WRF (St. Petersburg, FL) investigation of biological nutrient removal performance using phosphorous release tests, SNR tests and denitrification rate tests
- Investigation of impacts of gold mine leach pad RO brine on nitrification rate (private industry) using SNR tests
- Fritz Island WWTP (Reading, PA) wastewater characteristics and nitrification kinetics using lab-scale sequencing batch reactor method
- Thames Water Reading STW (Reading, United Kingdom) wastewater characteristics and nitrification kinetics using lab-scale sequencing batch reactor method
- Sulfolane degradation kinetics study (private industry)
- Elmira WWTP (Elmira, ON) detection of phosphorus accumulating organisms using phosphorous release test, measurement of influent biomass, measurement of nitrification kinetics using Washout method and inhibition screening using SNR tests.
- Hagersville WWTP (Hagersville, ON) study on impact of landfill leachate on nitrification kinetics using SNR tests
- Kitchener WWTP (Kitchener, ON) wastewater characteristics and nitrification kinetics using lab-scale sequencing batch reactor method
- Bonnybrook WWTP (Calgary, AB) wastewater characteristics and nitrification kinetics using lab-scale sequencing batch reactor method
- Guelph WWTP (Guelph, ON) nitrification inhibition testing
- Bran Sands WWTP (Middlesborough, UK) nitrification kinetics measurement using Washout method and industrial inhibition screening
- Hespeler WWTP (Hespeler, ON) full-scale sampling campaign design/sampling/analysis for wastewater characteristics and nitrification kinetics using High F/M method
- Guelph WWTP (Guelph, ON) wastewater characteristics and nitrification kinetics using lab-scale sequencing batch reactor method
- Galt WWTP (Galt, ON) full-scale sampling campaign design/sampling/analysis for wastewater characteristics
- Greeley WPCF (Greeley, CO) nitrification kinetics measurement using High F/M method
- Denver Metro WWTP (Denver, CO) nitrification kinetics measurement using High F/M method
- Blue Plains WWTP (Washington, DC) methanol-utilizing organisms kinetics measurement
- 75th Street WWTP (Boulder, CO) nitrification kinetics measurement using High F/M method
- Bradford West Gwillimbury WWTP (Bradford West Gwillimbury, ON) full-scale sampling campaign design/sampling/analysis for wastewater characteristics and nitrification kinetics using High F/M method
- Bonnybrook and Pine Creek WWTPs (Calgary, AB) wastewater characteristics and nitrification kinetics using lab-scale sequencing batch reactor method
Consulting Services
- Alberta Capital Region (Edmonton, AB) model calibration and model-based expansion and optimization.
- SD#28 Fairfield at St. James (NY, NY) model-based design.
- City of Clinton (Clinton, IA) model calibration and model-based capacity analysis.
- Disco Road Organics Processing Facility (Toronto, ON) model calibration and model-based capacity analysis.
- Magog WWTP (Magog, QC) model calibration and model-based capacity analysis.
- McAlpine Wastewater Treatment Plant (Pineville, NC): model calibration.
- City of Grand Island (Grand Island, NE): model calibration and model-based capacity analysis.
- Broadholme WRC (Wellingborough, UK): model calibration and model-based EBPR assessment.
- Hogsmill WWTP (Reading, UK): model calibration, validation and model-based future capacity analysis.
- Gatineau WWTP (Gatineau, Quebec): model calibration to historical data and application of applied model to assess the ability of proposed upgrades to secondary clarifiers to treat increased wet weather flows.
- Monmouth County Reclamation Centre (Monmouth County, NJ): model-based denitrification capacity analysis.
- Yad Hana WWTP (Israel): flow analysis, model calibration, preliminary design of process alternatives for the plant upgrade, detailed process design of selected alternative.
- Jebel Ali STP and Al Awir STP (Dubai Municipality, U.A.E.): flow analysis and model calibration
- Budds Farm WWTW (Southern Water, UK): model calibration and treatment upgrade optimization.
- Canadian National Biosolids Inventory (Environment Canada): modeling sludge production and sludge characteristics.
- Southwest Water Reclamation Facility (Manatee County, FL): model calibration and plant capacity assessment.
- Boulder WWTP (Boulder, CO): model calibration and energy audit.
- Oro Loma WWTP (San Lorenzo, CA): model calibration and optimization of nutrient removal
- Fort Dodge WWTP (Fort Dodge, IA): model calibration and application to assess plant capacity.
- Brushy Creek East WWTP (Brushy Creek, TX): wastewater characteristics measurement, model calibration, model-based design scenario analysis.
- Beckton STW (London, United Kingdom): model calibration and application of applied model to assess treatment plant ability to handle increased and extended peak flows arising from Thames Tideway Tunnel combined sewer overflow management. Model-based nitrification assessment.
- Fall Creek Regional Waste District (Pendleton, IN): wastewater characteristics measurement, model calibration, model-based optimization of design alternatives for chemical/biological phosphorous removal.
- Hammond WWTP (Hammond, WI): model calibration.
- Fritz Island WWTP (Reading, Pennsylvania): model calibration to existing trickling filter process and application of model to guide upgrade of process to biological nutrient removal activated sludge.
- Victor Harbor (Adelaide, South Australia): model calibration and application to assess ability of membrane bioreactor biological nutrient removal activated sludge process to meet lower effluent total nitrogen limits.
- Bonnybrook WWTP (Calgary, Alberta): model calibration and application to assess plant capacity.
- Gaoming WWTP (Gaoming, China): model calibration of an A2O oxidation ditch process, support for design of a sampling program for calibration, model-based scenario analysis, City of Foshan, Guangdong Province, China
- Shek Wu Hui STW (Hong Kong, China): modelling calibration and technology transfer to Drainage Services Department
- Hampton Roads Sanitation District York River, Nansemond, James River, Army Base and VIP WWTPs (Hampton Roads, Virginia): design of wastewater sampling programs, collection and analysis of historical data and simulator calibration.
- Bran Sands STW (Middlesborough, United Kingdom): model calibration for petrochemical and coke-oven wastewaters and pretreatment using a high rate anaerobic internal recirculation reactor.
- Broadneck WRF (Anne Arundel County, Maryland): model calibration, model-based design scenario analysis.
- Maryland City WRF (Anne Arundel County, Maryland): full-scale sampling campaign design/analysis, model calibration, model-based design scenario analysis.
- Guelph WWTP (Guelph, Ontario): wastewater characteristics measurement, model calibration.
- Galt WWTP (Region of Waterloo, Ontario): model calibration, model-based design scenario analysis.
- Skyway WWTP (Burlington, Ontario): model calibration and model-based feasibility investigation of additional sidestream treatment.
- Metropolitan Council Environmental Services Blue Lake and Seneca WWTPs (Minneapolis, Minnesota): nitrification kinetics measurement, model calibration, and capacity rating after retrofit to biological nutrient removal.